API RP 14F PDF

Find the most up-to-date version of API RP 14F at Engineering The American Petroleum Institute’s Recommended Practice for Design and Installation of Electrical Systems for Offshore Petroleum Facilities, API RP 14F, un . Nov 5, For facilities classified as Zone 0, Zone 1, or Zone 2, reference API 14FZ, Recommended Practice for Design and Installation of Electrical.

Author: Goltigore Gardarisar
Country: Malta
Language: English (Spanish)
Genre: Life
Published (Last): 16 May 2016
Pages: 116
PDF File Size: 19.11 Mb
ePub File Size: 4.91 Mb
ISBN: 337-5-25266-179-6
Downloads: 48196
Price: Free* [*Free Regsitration Required]
Uploader: Taular

Zone 2- Not likely or normally confined in containers.

30 CFR 250.114 – How must I install, maintain, and operate electrical equipment?

This is to provide a higher level of protection for their hazardous area equipment and personnel as they deem necessary.

Regulators such as U. Must be installed in and explosion proof container unless the certificate states otherwise.

All seals should be installed as close as practicable, but in no case more than 18 inches, from the enclosures to which they are attached. The classified areas are different and zpi protection concepts also differ. This recommended practice is intended to assist in development of a management program designed to promote safety and environmental protection during the performance of offshore oil and gas and sulphur operations.

Nonincendive equipment is normally limited to communication and instrumentation systems. This document recommends minimum requirements and guidelines for the design and installation of electrical systems on fixed and floating petroleum facilities located offshore when hazardous locations are classified as Zone 0, Zone 1, or Zone 2.

RP 14F, Electrical Systems for Offshore Petroleum Facilities, 6th ed.

Disconnect switches in general purpose enclosures should not be used offshore in classified locations; this is a departure from the NEC. Published by Nickolas Allan Jenkins Modified about 1 month ago.

This recommended practice is intended to assist in development of a management program designed to promote safety and environmental protection during the performance of offshore oil ro gas and sulphur operations. This equipment has additional security against the possibility of excessive temperature and the equipment is assembled very carefully to ensure that arcing or sparking apu part to part or connection to connection will not occur. Grounding of electrical equipment 14t fixed and floating offshore petroleum facilities in a positive manner is of particular importance because personnel standing on steel decks or in contact with steel framing present a low impedance path to ground, effectively grounded For sizing equipment grounding conductors, refer to NEC Table.

Most Related  ASTM D1835 PDF

This document recommends minimum requirements and guidelines for the design and installation of new piping systems on production platforms located offshore.

Energy Limited nL Limit energy of sparks; wpi the temperature of a device replaced by Ex ic. Inch, size or larger conduit run entering an enclosure that contains splices, taps, or terminals. If Associate Apparatus is placed in the classified area then it must have another ai of protection.

These advantages may include reduced initial capital expenditures, enhanced safety, or facilities that are more easily and more economically maintained. Zone 1 Equipment must be certified as meeting the requirements of the area this could be a number of different protection concepts not just Flame-Proof.

Metal-clad cable as defined by NEC Article This document recommends minimum requirements and guidelines for the design apu installation of electrical systems on fixed and floating petroleum facilities located offshore.

BSEE Safety Alert – Misuse of Beam Clamps as Ground (Electrical Grounds) – SAFTENG

Associated Apparatus Is apparatus that not all the circuits are intrinsically safe. C — Sparking equipment in which the contacts are suitably protected other than by restricted breathing.

Providing protection from fire, smoke, water and blast pressures. This Recommended Practice is intended to serve as a guide to crane owners and operators in developing operating and maintenance practices and procedures for use in the safe operation of pedestal-mounted revolving cranes on fixed or oating offshore platforms, jacku This document provides guidelines and recommended practice for the satisfactory design of offshore structures against fire and blast loading.

Type PLTC nonmetallic-sheathed, power-limited tray cable. Explosion proof equipment may not provide protection against the ingress of liquids or solids therefore, breathers and drains may be required. Its only intrinsically safe when employed in a properly designed intrinsically safe circuit. Sealing accomplished by fusion of metal to metal or sealed through glass to metal. This publication serves as a guide for those who are concerned with the design and construction of new platforms and for the relocation of existing platforms used for the drilling, development, and storage of hyd Applicable gas classification group s eg.

Most Related  AIRTRONICS RDS8000 MANUAL DOWNLOAD

Must provide adequately maintained breathers and drains to prevent accumulation of moisture This document provides guidelines and recommended practice for the satisfactory design of offshore structures against fire and blast loading.

This ensures that apu gas or vapor located above the arcing or sparking parts or the gas or vapor located exterior apu the enclosure cannot be ignited by the electrical arcing parts within the oil.

Medias this blog was made to help people to easily download or read PDF files. Why is it NOT acceptable? This recommended practice covers methods of installation for pressure-relief devices for equipment that has a maximum allowable working pressure MAWP of 15 psig 1.

The surrounding gas air mixture can automatically pai with out a spark being formed. Metal-clad cable for hazardous locations as defined in UL MI cable: As tested by the NFPA This document is intended to bring together in one place a brief description of basic desirable electrical practices for offshore electrical systems. This document recommends minimum requirements and guidelines for the design and installation of new piping systems on production platforms located offshore.

The procedures for installation of the instruments covered in this recommended practice are based on experience with and evaluation of many installations. If you wish to download it, please recommend it to your friends in any social system. Thus, the protection techniques for equipment to be installed in Zone 1 locations can be less demanding than the protection techniques for equipment to be installed in Division 1 locations. About project SlidePlayer Terms of Service.